Conditional Start Event
Add, copy, delete, change the color, align, and configure Conditional Start Event elements in your Process model.
Add a Conditional Start Event Element
Add a Conditional Start Event element from one of the following locations in Process Modeler:
Follow these steps to add a Conditional Start Event element from the Explorer panel to the Process model:
Locate the Start Event object category from one of the following locations in the Explorer panel:
Pinned Objects: The Start Event object category displays from the Pinned Objects section when it is pinned. This element type is pinned by default.
Object Category: The Start Event object category displays from the Object Category section when it is not pinned.
Its icon displays adjacent to the mouse icon to indicate this element type may be placed into the Process model.
Click the location in the Process model to place this element. If a Pool element is in your Process model, the Start Timer Event element cannot be placed outside of the Pool element.
After the element is placed into the Process model, you may adjust its location in the following ways:
Move the element by dragging it to a new location.
Moving a Conditional Start Event element has the following limitations in regards to the following Process model elements:
Pool element: If the Conditional Start Event element is inside of a Pool element, it cannot be moved outside of the Pool element. If you attempt to do so, Process Modeler places the Conditional Start Event element inside the Pool element closest to where you attempt to move it.
Lane element: If the Conditional Start Event element is inside of a Lane element, it can be moved to another Lane element in the same Pool element. However, the Conditional Start Event element cannot be moved outside of the Pool element.
Replace a Conditional Start Event Element with a Different Starting Request Event Element
The selected Conditional Start Event element is replaced by the default settings and color of the replacing element.
Follow these steps to replace a Conditional Start Event element with a different Start-type event element:
Select the Conditional Start Event element to change to another Start-type event element. Available options display above the selected element.
Click Confirm. The new element replaces the Conditional Start Event element with its default settings and color.
Settings
The Conditional Start Event element has the following panels that contain settings:
Configuration panel
Documentation panel
Advanced panel
Configuration Panel Settings
Edit the Element Name
An element name is a human-readable reference for a Process element. Process Modeler automatically assigns the name of a Process element with its element type. However, an element's name can be changed.
Follow these steps to edit the name for a Conditional Start Event element:
Select the Conditional Start Event element from the Process model in which to edit its name.
In the Name setting, edit the selected element's name and then press Enter.
Enter the Request Condition(s) that Triggers the Element
The Conditional Start Event ignores the call to start a Request in the following scenarios:
The Request condition(s) do not evaluate to the condition(s) set in the Condition setting.
The Request condition(s) evaluates as
null
.The Condition setting contains no value.
A Process model may use multiple Conditional Start Event elements. However, each Conditional Start Event element must use a unique condition for that element to trigger.
Follow these steps to enter the Request conditions that trigger a Conditional Start Event element:
Select the Conditional Start Event element from the Process model in which to edit its name.
Documentation Panel Settings
Edit the Element's Description Displayed in Process Documentation
Describe the element's purpose and how it functions in the Process. This description does not affect Requests for the Process, but may be useful for Process model maintenance such as how the element is configured. Edit information by using the What-You-See-Is-What-You-Get (WYSIWYG) rich text editor.
Follow these steps to edit the description for an element:
Select the element from the Process model in which to edit its description.
Follow these guidelines to use the WYSIWYG rich text editor to stylize your text:
Select the required text from the Rich Text control.
In the URL setting, enter the destination URL.
In the Text to display setting, edit or enter the text displayed in the Rich Text control.
In the Title setting, enter the text to display when a user hovers over the displayed text.
From Open link in… drop-down menu, select one of these options:
New window: Select this option to open the destination page in a new browser window.
Current window: Select this option to open the destination page in the current browser window.
In the Source setting, enter a URL for the image.
In the Alternative Description setting, enter the text to display if the source URL of the image is not accessible.
In the Width setting, enter the maximum width for the image.
In the Height setting, enter the maximum height for the image.
Click Save.
Format text: Follow these guidelines to format text:
Headings: From the Paragraph/Formats menu, select Headings and then select a heading size.
Bold: Do one of the following:
From the Paragraph/Formats menu, select Inline and then Bold.
Italics: Do one of the following:
From the Paragraph/Formats menu, select Inline and then Italic.
Underline: From the Paragraph/Formats menu, select Inline and then Underline.
Strikethrough: From the Paragraph/Formats menu, select Inline and then Strikethrough.
Superscript: From the Paragraph/ Formats menu, select Inline and then Superscript.
Subscript: From the Paragraph/Formats menu, select Inline and then Subscript.
Code: From the Paragraph/Formats menu, select Inline and then Code.
Paragraph: From the Paragraph/Formats menu, select Blocks and then Paragraph.
Blockquote: From the Paragraph/Formats menu, select Blocks and then Blockquote.
Division: From the Paragraph/Formats menu, select Blocks and then Div.
Preformatted: From the Paragraph/Formats menu, select Blocks and then Pre.
Select one of the color swatches from the color palette. The selected text changes to that color.
Align text: Follow these guidelines to align text:
Left align: Do one of the following:
From the Paragraph/Formats menu, select Align and then Left.
Center align: Do one of the following:
From the Paragraph/Formats menu, select Align and then Center.
Right align: Do one of the following:
From the Paragraph/Formats menu, select Align and then Right.
Justify: Do one of the following:
From the Paragraph/Formats menu, select Align and then Justify.
Advanced Panel Settings
Edit the Node's Identifier Value
Process Modeler automatically assigns a unique value to each Process node added to a Process model. However, a node's identifier value can be changed if it is unique to all other nodes in the Process model, including the Process model's identifier value.
All identifier values for all nodes in the Process model must be unique.
Follow these steps to edit the identifier value for a Conditional Start Event element:
Select the Conditional Start Event element from the Process model in which to edit its identifier value.
In the Node Identifier setting, edit the Conditional Start Event element's identifier to a unique value from all nodes in the Process model and then press Enter.
Last updated